320.00 Dollar US$ Relay coordination studies Chennai

Published date: September 7, 2022
  • Location: Porur, Chennai, Tamilnadu, India

RELAY COORDINATION STUDIES EXECUTIVE SUMMARY
Relay coordination studies – It is a well-known fact that the power system is not completely free from failures/faults. The key here is to mitigate the consequences during the event of faults. Damage to equipment during a fault can be reduced by quickly isolating the faulty portion from the rest of the health system. The objective of the protection coordination study is to determine optimum settings for protection devices such that the protection system isolates the minimum possible faulty portion at the earliest possible to ensure a reliable power supply for the health system. The optimum settings ensure required sensitivity and selectivity that protect workers from harm as well. The software used for the protection coordination study is ETAP, DigSilent Power factory, PSCAD, and PSS/E. The protection coordination study involves protection devices from various manufacturers such as Siemens, ABB/Hitachi, GE, Schneider, and so on.
WHY RELAY COORDINATION STUDY?
• To determine the optimum settings for protective devices in the system such as relays, releases, breakers, etc to ensure that proper coordination is achieved.
• To analyze time coordination curves (TCC) to verify the coordination between upstream and downstream protection devices including fuses.
• To check the sequence of operation of protection devices for various operating configurations.
• To find out the fault clearing time.
• To verify the protection coordination of t existing plant especially when there is a change in the network connectivity or source fault level.
• To generate calculations and finalize the unit protection settings of a generator, line, cable, transformer, motor, reactor, and capacitor banks.
• As an input for the calculation of incident energy in Arc Flash Studies.
HOW RELAY COORDINATION STUDY? (METHODOLOGY)
• Collection of inputs (SLD, equipment parameters – Voltage kV rating, Power MVA rating, Impedance, System fault level, X/R ratio, relay details, protection schematics, etc.)
• Modelling in study software.
• Carry out the short circuit simulations for various system configurations (normal and contingency configuration)
• Generating TCC curves and determining the characteristics and optimum settings
• Verification of sequence of operation for different types of faults (3 Ph, SLG, L-L, L-L-N) at various locations.
• Generating relay setting tables/charts, relay settings soft file (parameterization) file.
• Submission of detailed report.
• Presentation of study findings.
OUTCOMES OF RELAY COORDINATION STUDY
• Detailed report explaining the input data, system configuration, observations, and recommendations
• Fault currents at various buses and branches in the system.
• Relay setting charts/tables with optimum settings
• Time coordination curves
• Sequence of operation
• Relay setting soft file
• Input to Arc Flash Study
REFERENCE
• IEEE 242 – Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems
• IEEE 3004 Standards: Protection & Coordination
• IEEE 399 – Recommended Practice for Industrial and Commercial Power System Analysis
• IEEE 241 – Recommended Practice for Electric Power Systems in Commercial Buildings
• IEC 60255 Measuring relays and protection equipment

Know more,
Visit  https://powerprojectsindia.com/relay-coordination-studies/
Follow us on
LinkedIn  https://www.linkedin.com/company/power-projects/
Youtube  https://www.youtube.com/c/PowerProjects_etap/featured
Website  https://powerprojectsindia.com/
Facebook (META)  https://www.facebook.com/powerprojects4u
Instagram  https://instagram.com/powerprojectsindia?igshid=YmMyMTA2M2Y=
Whatsapp  +91 8807558338

Contact seller


Share

Useful information

  • Avoid scams by acting locally or paying with PayPal
  • Never pay with Western Union, Moneygram or other anonymous payment services
  • Don't buy or sell outside of your country. Don't accept cashier cheques from outside your country
  • This site is never involved in any transaction, and does not handle payments, shipping, guarantee transactions, provide escrow services, or offer "buyer protection" or "seller certification"

Related listings



  • Relay coordination studies
    Relay coordination studies
    Tutoring - Private Lessons - Chennai (Tamilnadu) - September 7, 2022 320.00 Dollar US$

    RELAY COORDINATION STUDIES EXECUTIVE SUMMARY Relay coordination studies – It is a well-known fact that the power system is not completely free from failures/faults. The key here is to mitigate the consequences during the event of faults. Damage to eq...

  • Arc Flash Study
    Arc Flash Study
    Tutoring - Private Lessons - Chennai (Tamilnadu) - September 7, 2022 157.00 Dollar US$

    Arc Flash studies – An arc flash is a phenomenon where a flash-over of electric current leaves its intended path and travels through the air from one conductor to another or the ground. The results are often violent and when a human is close to the a...

  • Professional f1 racing academy in India - Ahura Racing
    Professional f1 racing academy in India - Ahura Racing
    Tutoring - Private Lessons - Coimbatore (Tamilnadu) - August 18, 2022 641048.00 Dollar US$

    Ahura racing is an f1 racing academy in India, our team management provides formula race car drivers guidance and training. We exist to win in everything we do